ECG Axis Interpretation (2024)

Cardiac axis represents the sum of depolarisation vectors generated by individual cardiac myocytes. Clinically is is reflected by the ventricular axis, and interpretation relies on determining the relationship between the QRS axis and limb leads of the ECG (below diagram)

Since the left ventricle makes up most of the heart muscle under normal circ*mstances, normal cardiac axis is directed downward and slightly to the left:

  • Normal Axis= QRS axis between -30° and +90°.

Abnormal axis deviation, indicating underlying pathology, is demonstrated by:

  • Left Axis Deviation= QRS axis less than -30°.
  • Right Axis Deviation= QRS axis greater than +90°.
  • Extreme Axis Deviation= QRS axis between -90° and 180° (AKA “Northwest Axis”).

Note that in paediatric ECG interpretation, the cardiac axis lies between +30 to +190 degrees at birth and moves leftward with age.

Methods of ECG Axis Interpretation

There are several complementary approaches to estimating QRS axis, which are summarized below:

  • The Quadrant Method– (Lead I and aVF)
  • Three Lead analysis– (Lead I, Lead II and aVF)
  • Isoelectric Lead analysis
  • Super SAM the Axis Man

Method 1 – The Quadrant Method

The most efficient way to estimate axis is to look at LEAD I and LEAD aVF.

Examine the QRS complex in each lead and determine if it is Positive, Isoelectric (Equiphasic) or Negative:

  • Apositive QRSinLead Iputs the axis in roughly the same direction as lead I.
  • Apositive QRSinLead aVFsimilarly aligns the axis with lead aVF.
  • Combining both coloured areas – the quadrant of overlap determines the axis. So If Lead I and aVF are bothpositive, the axis is between 0° and +90° (i.e. normal axis).
Now estimate the AXIS using the Lead I and aVF – Quadrant Method:
AXIS: QRS Positive Lead I – QRS Negative Lead aVF
AXIS: QRS Negative Lead I – QRS Positive Lead aVF
AXIS: QRS Negative Lead I – QRS Negative Lead aVF
Summary Table:

Note: **Possible LAD can be further evaluated using Lead II as detailed in method 2 below…

Method 2: Three Lead analysis – (Lead I, Lead II and aVF)

Next we add in Lead II to the analysis of Lead I and aVF

  • Apositive QRSinLead Iputs the axis in roughly the same direction as lead I.
  • Apositive QRSinLead IIsimilarly aligns the axis with lead II.
  • We can then combine both coloured areas and the area of overlap determines the axis. So If Lead I and II arebothpositive, the axis is between -30° and +90° (i.e. normal axis).
  • The combined evaluation of LeadI,LeadIIandaVF– allows rapid and accurate QRS assessment. The addition of LeadIIcan help determine pathological LAD from normal axis/physiological LAD
  • Note:Lead IIIoraVFcanbothbe used in three lead analysis

Now estimate the AXIS using Three Lead analysis:

QRS Positive Lead I – QRS Equiphasic Lead II – QRS Negative Lead aVF
ECG Axis Interpretation (10)
QRS Positive Lead I – QRS Negative Lead II – QRS Negative Lead aVF
QRS Negative Lead I – QRS Positive Lead II – QRS Positive Lead aVF
QRS Negative Lead I – QRS Negative Lead II – QRS Negative Lead aVF
Summary Table:

Method 3 – The Isoelectric Lead

This method allows a more precise estimation of QRS axis, using the axis diagram below.

Key Principles

  • If the QRS isPOSITIVEin any given lead, the axis points inroughlythesame directionas this lead.
  • If the QRS isNEGATIVEin any given lead, the axis points inroughlytheopposite directionto this lead.
  • If the QRS isISOELECTRIC(equiphasic) in any given lead (positive deflection = negative deflection), the axis is at 90° to this lead.

Step 1: Find the isoelectric lead. The isoelectric (equiphasic) lead is the frontal lead with zero net amplitude. This can be either:

  • A biphasic QRS where R wave height = Q or S wave depth.
  • A flat-line QRS with no discernible features.

Step 2: Find the positive leads.

  • Look for the leads with the tallest R waves (or largest R/S ratios)

Step 3: Calculate the QRS axis.

  • The QRS axis is at90°to the isoelectric lead, pointingin the directionof the positive leads.

This concept can be difficult to understand at first, and is best illustrated by some examples.

Examples

Example 1
Answer – Lead I, II, aVF
  • Lead I =POSITIVE
  • Lead II =POSITIVE
  • aVF =POSITIVE
  • This puts the axis in the quadrant between 0° and +90° – i.e.normal axis
Answer – Isoelectric Lead Method

Lead aVL is isoelectric, being biphasic with similarly sized positive and negative deflections (no need to precisely measure this).

  • From the diagram above, we can see thataVL is located at -30°.
  • The QRS axis must be ± 90° from lead aVL, either at +60° or -120°
  • With leadsI(0),II(+60) andaVF(+90) all being positive, we know that the axis must lie somewhere between 0 and +90°.
  • This puts the QRS axis at+60° –i.e.normal axis
Example 2
Answer – Quadrant Method
  • Lead I =NEGATIVE
  • Lead II =Equiphasic
  • Lead aVF =POSITIVE
  • This puts the axis in the quadrant, between +90° and +180°, i.e.RAD.
Answer – Isoelectric Lead Method
  • Lead II(+60°) is theisoelectric lead.
  • The QRS axis must be ± 90° from lead II, at either +150° or -30°.
  • The more rightward-facing leads III (+120°) and aVF (+90°) are positive, while aVL (-30°) is negative.
  • This puts the QRS axis at +150°.

This is an example of right axis deviation secondary to right ventricular hypertrophy.

Example 3
Answer – Quadrant Method
  • Lead I =POSITIVE
  • Lead II =Equiphasic
  • Lead aVF =NEGATIVE
  • This puts the axis in the quadrant between 0° and -90°, i.e. normal or LAD.
  • Lead II is neither positive nor negative (isoelectric), indicating physiological LAD.
Answer – Isoelectric Lead Method
  • Lead II(+60°) isisoelectric.
  • The QRS axis must be ± 90° from lead II, at either +150° or -30°.
  • The more leftward-facing leads I (0°) and aVL (-30°) are positive, while lead III (+120°) is negative.
  • This confirms that the axis is at -30°.

This is an example of borderline left axis deviation due to inferior MI.

Example 4
Answer – Quadrant Method
  • Lead I =NEGATIVE
  • Lead II =NEGATIVE
  • Lead aVF =NEGATIVE
  • This puts the axis in the upper right quadrant, between -90° and 180°, i.e.extreme axis deviation.

NB. The presence of a positive QRS in aVR with negative QRS in multiple leads is another clue to the presence of extreme axis deviation.

Answer – Isoelectric Lead Method
  • The most isoelectric lead is aVL (-30°).
  • The QRS axis must be at ± 90° from aVL at either +60° or -120°.
  • Lead aVR (-150°) is positive, with lead II (+60°) negative.
  • This puts the axis at -120°.

This is an example of extreme axis deviation due to ventricular tachycardia.

Example 5
Reveal answer
  • Lead I = isoelectric.
  • Lead aVF = positive.
  • This is the easiest axis you will ever have to calculate. It has to be at right angles to lead I and in the direction of aVF, which makes it exactly +90°!

This is referred to as a “vertical axis” and is seen in patients with emphysema who typically have a vertically orientated heart.

Causes of Axis Deviation

Right Axis Deviation
  • Right ventricular hypertrophy
  • Acuteright ventricular strain, e.g. due topulmonary embolism
  • Lateral STEMI
  • Chronic lung disease, e.g. COPD
  • Hyperkalaemia
  • Sodium-channel blockade, e.g. TCA poisoning
  • Wolff-Parkinson-White syndrome
  • Dextrocardia
  • Ventricular ectopy
  • Secundum ASD – rSR’ pattern
  • Normal paediatric ECG
  • Left posterior fascicular block– diagnosis of exclusion
  • Vertically orientated heart – tall, thin patient
Left Axis Deviation
  • Left ventricular hypertrophy
  • Left bundle branch block
  • Inferior MI
  • Ventricular pacing/ectopy
  • Wolff-Parkinson-White Syndrome
  • Primum ASD – rSR’ pattern
  • Left anterior fascicular block– diagnosis of exclusion
  • Horizontally orientated heart – short, squat patient
Extreme Axis Deviation
  • Ventricular rhythms – e.g.VT,AIVR,ventricular ectopy
  • Hyperkalaemia
  • Severeright ventricular hypertrophy
Further Reading

For a deeper understanding of axis determination, including a detailed explanation of the hexaxial reference system, check out this excellent series of articles from EMS 12-lead.

Further reading

Online

Textbooks

[cite]

ECG LIBRARY

more EKG…

Mike Cadogan

BA MA (Oxon) MBChB (Edin) FACEM FFSEM. Emergency physician, Sir Charles Gairdner Hospital. Passion for rugby; medical history; medical education; and asynchronous learning #FOAMed evangelist. Co-founder and CTO of Life in the Fast lane | Eponyms | Books | Twitter |

Robert Buttner

MBBS (UWA) CCPU (RCE, Biliary, DVT, E-FAST, AAA) Adult/Paediatric Emergency Medicine Advanced Trainee in Melbourne, Australia. Special interests in diagnostic and procedural ultrasound, medical education, and ECG interpretation. Editor-in-chief of the LITFL ECG Library. Twitter: @rob_buttner

ECG Axis Interpretation (2024)
Top Articles
Latest Posts
Article information

Author: Catherine Tremblay

Last Updated:

Views: 6356

Rating: 4.7 / 5 (67 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Catherine Tremblay

Birthday: 1999-09-23

Address: Suite 461 73643 Sherril Loaf, Dickinsonland, AZ 47941-2379

Phone: +2678139151039

Job: International Administration Supervisor

Hobby: Dowsing, Snowboarding, Rowing, Beekeeping, Calligraphy, Shooting, Air sports

Introduction: My name is Catherine Tremblay, I am a precious, perfect, tasty, enthusiastic, inexpensive, vast, kind person who loves writing and wants to share my knowledge and understanding with you.